Portées maximales d’utilisation des panneaux THPR FONO
Ep.mm | Coefficient de transmission thermique : W/m². °C | Poids Kg/m² | Charges non pondérées daN/m² |
| 50 | 60 | 80 | 100 | 120 | 140 | 160 | 180 | 200 |
50 |
0.75 |
14.50 |
3.05 |
2.80 |
2.40 |
2.10 |
1.85 |
1.70 |
1.60 |
1.50 |
1.40 |
60 |
0.62 |
15.50 |
3.55 |
3.20 |
2.75 |
2.40 |
2.20 |
2.00 |
1.80 |
1.65 |
1.60 |
80 |
0.49 |
17.20 |
4.40 |
4.00 |
3.45 |
3.05 |
2.75 |
2.75 |
2.30 |
2.15 |
2.00 |
100 |
0.39 |
19.00 |
5.00 |
4.60 |
3.95 |
3.20 |
3.20 |
3.00 |
2.80 |
2.60 |
2.40 |
120 |
0.33 |
21.40 |
5.45 |
5.00 |
4.35 |
3.80 |
3.55 |
3.30 |
3.05 |
2.90 |
2.80 |
150 |
0.27 |
24.40 |
6.00 |
5.60 |
4.90 |
4.30 |
3.95 |
3.70 |
3.45 |
3.25 |
3.10 |
Ep.mm | Coefficient de transmission thermique : W/m². °C | Poids Kg/m² | Charges non pondérées daN/m² |
| 50 | 60 | 80 | 100 | 120 | 140 | 160 | 180 | 200 |
50 |
0.75 |
14.50 |
3.55 |
3.15 |
2.65 |
2.25 |
2.00 |
1.80 |
1.60 |
1.50 |
1.40 |
60 |
0.62 |
15.50 |
4.10 |
3.70 |
3.05 |
2.65 |
2.35 |
2.10 |
1.95 |
1.75 |
1.60 |
80 |
0.49 |
17.20 |
4.80 |
4.35 |
3.70 |
3.30 |
3.00 |
2.75 |
2.50 |
2.25 |
2.10 |
100 |
0.39 |
19.00 |
5.40 |
4.80 |
4.10 |
3.60 |
3.30 |
3.00 |
2.80 |
2.60 |
2.45 |
120 |
0.33 |
21.40 |
5.80 |
5.20 |
4.40 |
3.85 |
3.45 |
3.20 |
3.00 |
2.80 |
2.60 |
150 |
0.27 |
24.40 |
6.10 |
5.70 |
4.80 |
4.20 |
3.80 |
3.45 |
3.20 |
3.00 |
2.80 |
Les valeurs indiquées dans les tableaux ci-dessus prévoient une flèche f < l/200 des écartements des appuis l(m) et se réfèrent aux panneaux avec épaisseurs des parements aciers 0.6 mm.